- Demand-controlled ventilation in a specific indoor area, such as a conference room, classroom, meeting hall, etc.
Telaire T5100-LED Series
Wall Mount CO2 Transmitter
Telaire T5100-LED Series of Wall Mount CO2 Transmitters offers low cost, high performance CO2 transmitters for the building controls market. It works seamlessly with building automation systems, and allows you to simply and effectively control fresh air into a ventilated space to regulated standards, providing immediate energy savings.
- Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package
- Patented ABC Logic™ self-calibration system eliminates the need for manual calibration in most applications
- Lifetime CO2 calibration guarantee when using ABC Logic™
- Mounting plate with two-piece terminal blocks provide quick, easy wiring
- Gas permeable, water resistant CO2 diffusion filter prevents particulate and water contamination of the sensor
- Locking screw secures cover and sensor to the mounting bracket for tamper resistance
- Sensors are shipped factory calibrated
- Modern enclosure
- Low cost
- Reliable (20 years of low-cost infrared sensor manufacturing)
- Available CO2 and Temperature output options: Voltage 0-10V or 0-5V (switch selectable) or current 4-20 mA
- UIP software compatible for customizations
- CE, RoHS, REACH and WEEE compliant
- Lifetime calibration warranty
- Two enclosure sizes for regional acceptance
Sensing Method | Non-dispersive infrared (NDIR) absorption Gold-plated optics Patented ABC Logic self calibration algorithm |
---|---|
CO2 Measurement Range | 0 to 2000 ppm (0 ppm = 0 V, 4 mA) |
CO2 Accuracy | ±30 ppm or 3% of the reading shown, whichever is higher * |
Active Temperature Accuracy /Range | 0-50°C (32-122°F) ±1°C from 15-30°C (±1.8°F from 59 to 86°F) |
Power Supply Requirements | 18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, polarity protected *AHRAE — regulation 62 states maximum indoor CO2 level of 1000 ppm |
Power Consumption |
Typical 0.7 W at nominal voltage of 24V AC RMS |
Temperature Dependence | 0.2% FS per °C (±0.11% per °F) |
Stability | <2% of FS over life of sensor (15 years) |
Pressure Dependence | 0.135% of reading per mm Hg |
English
English
Demand Control Ventilation Q&A - Telaire Application Note
Common CO2 Wiring Issues - Telaire Application Note
CO2-based Ventilation Control | Where Required and Recommended - Telaire Application Note
CO2 Sensor Sniffs Out Human Smugglers - Telaire Application Note
Carbon Dioxide (CO2) and Combustion Sensing - Telaire Application Note
ABCLogic™ Self Calibration Feature - Telaire Application Note
English
T5100-V