- In building monitoring systems, allowing for quick, easy and efficient monitoring the building air quality to stay within regulation
- Indoor growing and horticulture
- HVAC controls in continuously occupied commercial buildings
Telaire T6615
Dual Channel CO2 Sensor Module
Telaire T6615 is a Dual Channel CO2 Sensor Module designed to integrate into existing controls and equipment for use in instumentation and applications up to 50,000 ppm. Dual channels consist of one CO2 channel that measures gas concentration and one reference channel that measures the sensor signal intensity.
- An affordable gas sensing solution for OEMs
- A reliable sensor design based on 15 years of engineering and manufacturing expertise
- Flexible CO2 sensor platform designed to interact with other microprocessor devices
- Dual-channel optical system and three-point calibration process for enhanced stability, accuracy and reliability
- Designed for applications where ABC Logic cannot be used
The Telaire T6615 Series CO2 Sensor evaluation kit enables quick and easy operation of Telaire’s NDIR CO2 sensor modules through a standard PC interface. The kit provides a cost-effective development tool and includes:
- USB drive with applicable software and user instructions
- USB sensor interconnect cable
- Two T6615 sensors with 6 pin header
Method | Dual-channel non-dispersive infrared (NDIR), gold plated optics, diffusion or flow through sampling |
---|---|
Measurement Range | 0 to 2000 ppm 0 to 5000 ppm 0 to 10,000 ppm 0 to 50,000 ppm |
Dimensions | 2.25 in X 1.365 in X 0.60 in (57.15 mm X 34.67 mm X 15.24 mm) |
Accuracy* | 400-1000 ppm, ±75ppm >1000ppm, ±10% of reading |
Temperature Dependence | 0.2% FS per °C |
Stability over Life of Sensor (10 Years) | < 5% of FS or <10% reading annual |
Pressure Dependence | 0.135% of reading per mm Hg |
Response Time | < 2 minutes for 90% step change typical |
Warm Up Time | < 2 minutes (operational) 10 minutes (maximum accuracy) |
Operating Conditions | 32°F to 122°F (0°C to 50°C) 0 to 95% RH, non condensing |
Storage Conditions | -40°F to 158°F (-40°C to 60°C) (Non Condensating) |
English
English
Demand Control Ventilation Q&A - Telaire Application Note
Common CO2 Wiring Issues - Telaire Application Note
CO2-based Ventilation Control | Where Required and Recommended - Telaire Application Note
CO2 Sensor Sniffs Out Human Smugglers - Telaire Application Note
Carbon Dioxide (CO2) and Combustion Sensing - Telaire Application Note
ABCLogic™ Self Calibration Feature - Telaire Application Note
English
- T6615
- T6615-5K
- T6615-10K
- T6615-50K
- T6615-F
- T6615-5KF
- T6615-10KF
- T6615-50KF
- T6615-R12
- T6615-EVAL